🏭 Manufacturer since 2013 · IEC / GB Standards · OEM & ODM Welcome
📧 sales@jingminelectric.com  |  📱 WhatsApp / WeChat: +86 130 9198 8913

Box-Type Substations & E-Houses

European & American type package substations, compact substations and prefabricated substation modules from 10kV to 35kV.

Overview

A box-type (package) substation puts the HV switchgear, transformer and LV distribution board together in one factory-assembled enclosure. It arrives on site ready to cable up — cutting civil works, installation time and land use compared with a conventional brick-built substation.

We build the whole package in-house: enclosure, HV ring main unit or switch-fuse unit, transformer and LV board. You get one drawing set, one test report and one shipment.

  • 10 kV, 20 kV and 35 kV versions
  • Transformer capacity 50–2500 kVA (single or double transformer)
  • European type, American pad-mounted and compact layouts
  • Steel, stainless steel or GRP enclosure, IP33–IP54
  • Optional lighting, ventilation, heating, dehumidifier and remote monitoring
Delivery format: complete, factory-tested and pre-wired, shipped as one or more units.

On-site work reduced to: foundation, positioning, HV cable termination, LV cable connection and commissioning checks.

YBW-12 European Type Box Substation

Three-compartment layout — HV room, transformer room and LV room — with a walk-in or non-walk-in option and metal-clad partitions between rooms.

YBW-12 — typical technical data
ParameterUnitValue
Rated HV voltagekV12 (24 / 40.5 available)
Rated LV voltageV400 / 415 / 440 (as required)
Transformer capacitykVA50 / 100 / 125 / 160 / 200 / 250 / 315 / 400 / 500 / 630 / 800 / 1000 / 1250 / 1600 / 2000
HV side configuration—Ring main unit (C–F–V) or switch–fuse unit, 2–4 ways
LV side configuration—Main incomer + 4–12 outgoing feeders, with or without reactive compensation
Rated HV currentA630
HV short-circuit withstand (3–4 s)kA20
LV main busbarAUp to 3200, Icw 50 kA / 1 s (typical)
Enclosure—2.0–2.5 mm galvanised steel / stainless steel / GRP composite
Surface treatment—Shot blast, zinc-rich primer, epoxy intermediate, UV-resistant topcoat
Degree of protection—IP33 (standard) / IP54 (optional)
Ambient temperature°C−25 to +40
Relative humidity%Up to 95, non-condensing
Standards—IEC 62271-202, GB/T 17467

Dimensions depend on transformer size, compartment layout and walk-in requirement — tell us the capacity and site conditions and we will supply a layout drawing.

Other Substation Formats

Different sites need different packages — the electrical core stays the same.

MB American Type Pad-Mounted

A single sealed tank combining HV switch, transformer and LV panel, mounted on a concrete pad. Compact footprint, cable entry from below, ideal for residential areas, parks and streetscapes.

  • 50–1000 kVA
  • 10 kV / 0.4 kV
  • HV: load break switch + fuse or elbow connector

ZB / ZBW Compact Substation

Minimal two-compartment layout where floor space is tight — HV switch and transformer share one room with a barrier, LV board in the second. Lower cost, smaller footprint.

  • 100–1250 kVA
  • 10–35 kV
  • Non-walk-in, front-access design

Prefabricated Substation / E-House

Container-style modules with multiple rooms for larger projects: HV switchgear room, transformer room, LV room, control room and battery room, fully wired and tested before shipment.

  • Multiple transformers per house
  • Walk-in, HVAC, fire detection
  • Designed to site seismic & wind loads

How to Specify Yours

Send us these six items and we can quote accurately
#Information neededWhy it matters
1HV system voltage & short-circuit levelDetermines RMU rating and cable box size
2Transformer capacity and vector groupFixes enclosure dimensions and LV busbar
3Number and rating of LV outgoing feedersSizes the LV board and cabinet width
4Ambient temperature, altitude, humidity, wind/seismicAffects insulation, cooling and structure
5Enclosure preference (steel / stainless / GRP) and IP ratingCost and corrosion resistance
6Metering, compensation and automation requirementsSecondary equipment and wiring scope

Tell Us About Your Site

Send the transformer capacity, incoming voltage and required outgoing feeders — we will propose a layout and quote the complete package, FOB Shanghai or CIF your port.