🏭 Manufacturer since 2013 · IEC / GB Standards · OEM & ODM Welcome
📧 sales@jingminelectric.com  |  📱 WhatsApp / WeChat: +86 130 9198 8913

LV Switchgear & Distribution Boards

Fixed and withdrawable low voltage assemblies up to 6300A for industrial plants, buildings and utility projects.

Overview

Low voltage switchgear is where most projects are actually won or lost — it is the board the client sees every day, the one that must absorb every feeder change without a shutdown, and the one that has to pass the local inspector.

We build fixed, withdrawable and modular assemblies up to 6300 A, using internationally available breakers (or your preferred brand), with busbars sized and braced to the short-circuit level you specify.

  • Rated current from 400 A to 6300 A
  • Rated insulation voltage 690 V, working voltage 400 / 415 / 440 / 690 V
  • Short-time withstand current up to 100 kA / 1 s
  • Form 1 to Form 4 internal separation on request
  • Copper or aluminium busbars, tinned and sleeved
  • Built and tested to IEC 61439-1 / IEC 61439-2
Breaker brands: we can build around the breakers your market already stocks — ABB, Schneider, Siemens, LS, Chint, Delixi or our own selection for economy schemes.

Documents supplied: GA drawing, single-line diagram, wiring diagram, routine test report, breaker certificates, manual.

GGD — Fixed Type LV Switchgear

The economical choice for distribution rooms, pump houses and workshops where feeders rarely change. Robust frame, generous wiring space, easy to maintain.

GGD — typical technical data
ParameterUnitValue
Rated insulation voltageV690
Rated working voltageV400 / 415 / 440 / 690
Rated frequencyHz50 / 60
Rated current of main busbarA400 / 630 / 800 / 1000 / 1250 / 1600 / 2000 / 2500 / 3200
Rated short-time withstand currentkA15 / 30 / 50 (1 s, typical)
Rated peak withstand currentkA30 / 63 / 105 (typical)
Internal separation—Form 1–Form 2 (optional Form 3b)
Degree of protection—IP30 (standard) / IP40 / IP54
Typical cabinet widthmm600 / 800 / 1000 / 1200
Standards—IEC 61439-1 / -2, GB 7251.1

GCK / GCS / MNS — Withdrawable & Modular Assemblies

When a plant cannot afford a long shutdown, withdrawable functional units let maintenance happen on a live board. These are the three standard Chinese modular systems, in ascending order of current rating and accessibility.

Withdrawable LV switchgear comparison — typical data
SystemTypeMax rated currentShort-time withstandTypical use
GCKWithdrawable, standard modular3150 Aup to 80 kA / 1 sGeneral industrial distribution, pump and fan control
GCSWithdrawable, modular, higher rating4000 Aup to 100 kA / 1 sLarge plants, substation LV side, MCC
MNSModular, 25 mm module, full Form 46300 Aup to 100 kA / 1 sData centres, refineries, critical process plants
XL-21Fixed, single-front power cabinet630 A15–30 kA / 1 sSmall distribution, machine-side power
JPIntegrated distribution box400 A15 kA / 1 sPole-mounted rural and residential distribution

Functional units

Incomer, bus-tie, motor starter (DOL / star-delta / soft start / VFD), capacitor, feeder and metering units — all built as interchangeable drawers.

Internal separation

Form 1 through Form 4b: busbars, functional units, terminals and cable ways separated to the degree your specification or insurer requires.

Metering & control

Digital multi-function meters, power quality analysers, PLC control, ATS/AMF logic and optional Modbus TCP / IEC 61850 gateways.

What We Need to Quote Precisely

ItemDetail
System dataRated voltage, frequency, prospective short-circuit current and duration
Main busbarRated current, copper or aluminium, incoming arrangement (single or double ended)
Circuit listEach feeder: rating, breaker type (ACB / MCCB / MCB), function, cable size, protection setting
Motor startersMotor rating, starting method, control voltage, local or remote
CompensationRequired kVAr, automatic stages, detuned reactor (for harmonic-rich plants)
LayoutRoom dimensions, cable entry direction, front / rear access, transport constraints
EnvironmentAmbient temperature, altitude, humidity, dust, corrosive atmosphere
Standards & markingIEC or local standard, IP rating, language of labels and manuals

A single-line diagram plus a circuit list is usually enough for a firm quotation. If you only have a load summary, send that — we can help you build the circuit list.

Get Your LV Board Quoted

Send the single-line diagram or load list. We will confirm the busbar rating, breaker selection and price within 24 hours.

Chat on WhatsApp